6. Switch SW3 is used to enable/disable the
internal/external wired magnetic contact.
Position of SW3 Function
INT. Internal Contact ON
INT./EXT. Internal and External
Contacts ON
7. Set the Door/Window Detector by setting the
position of the switch (SW3).
If setting to the INT. position, only the internal
contact will be active. When two contacts are in
use for internal and external connection
simultaneously (INT./EXT. position), only one
activation will be counted if one of the contacts is
opened. If one contact is left open and the other
closed contact is opened then an activation will
be counted.
If using external contacts wired to the Detector,
set to the INT./EXT. position.
8. Refit the battery cover.
TESTING A MAGNETIC DOOR/WINDOW
DETECTOR INDEPENDENTLY
9.
Remove battery cover to activate the tamper switch.
As the button is released the LED indicator will
illuminate for approximately 1 second to show
that the tamper switch has been triggered and a
signal is being transmitted.
10. Open the door/window to remove the Magnet
from the Detector.
As the Magnet is moved away from the Detector
the LED indicator will illuminate for
approximately 1 second to show that the
Detector has been triggered and a signal is
being transmitted.
Note: It does not matter if the LED indicator
illuminates as the magnet is brought towards
the detector.
LINKING A MAGNETIC DOOR/WINDOW
DETECTOR TO THE CONTROL PANEL
1. Remove the battery cover after installing and
configuring it.
2.
With the system in Standby
Press
to enter Program Mode.
3. Scroll through the programming menu until
‘3. ZONE SETUP’ is displayed and press .
4.
Enter the zone number to be configured (1 - 36)
and press .
Note: Zones 33-36 the wired zones are the
same except there is no learn menu option as
these are wired.
5. To learn a new detector ID code and link it to the
selected zone
press .
The panel will now listen for a valid signal from
a new detector to link to the zone.
The Panel will remain in Learn Mode for 30s.
If a valid signal is not received from a new
detector within 30s it will automatically exit
Learn Mode and return to the top of level 3.1
19