21
TESTING THE SYSTEM
The Control Panel has a built in test facility to enable
you to test the system at any time. However it is
recommended that the system is tested at regular
intervals not exceeding 3 months.
The Control Unit incorporates a terminal block for
connection of hard-wired zones (7-10) and a wired
Siren unit. The connection terminal block is located
inside the Control Panel behind the front cover. To
access the terminal block you must rst put the system
into Test Mode to prevent an alarm occurring.
To do this:
Press
Undo the two xing screws on the top edge of the
Control Panel and open the front cover.
Before making any connections, ensure that the Reset
Jumper Link P1 is in the ’OFF’ position and then
remove the DC power jack and disconnect 1 of the
back-up batteries.
The hardwired zone and tamper switches should be
volt free and normally closed, with the contacts opening
in order to trigger an alarm.
Note: Jumper Link P51 should be tted into the ON
position only if the external hardwired tamper circuit is
used, otherwise it must be in the OFF position.
After making your external connections reconnect the
power supply and Back-up Battery. Then close the
Control Panel cover and tighten the screws on the top
edge of the Control Panel.
Press to leave Test mode and return to Standby.
With the system in Standby press
The Arm and Part-Arm LEDs will ash.
The system is now in Test Mode.
Use the and buttons to scroll through the
menu and press to select the displayed test
function or sub-menu.
Note: After completing all required test functions press
to leave Test Mode and return to Standby.
DETECTOR TEST
Before commencing testing please ensure that there
is no movement in any PIR protected area, all doors/
windows protected by Magnetic Contact Detectors are
closed and that all battery covers and housings are
correctly tted.
Note: It may be helpful to have a 2
nd
person to assist
with this test.
press ENTER
Relay Test
Replay ON for 5s
Stop->ESC
Wirefree Siren
Test
Hardwired Siren
Test
WALK TEST
TEST MODE
Code:
Voice Dialler
Test
Test phone No._
Stop->ESC
Remote Manager
Test
ALARM TEST
Walk Test
Waiting…
Wirefree Siren
Service ON/OFF
Service ON/OFF
Wait for 10s
press ENTER
press ENTER press ENTER press ENTER
press ENTER
press ENTER press ENTER
Siren ON for 5s
Stop->ESC
Siren ON for 5s
Stop->ESC
Remote Manager
Test…wait
User Access Code
User Access Code