WIRE FREE SIREN TEST
Press
The External Solar Siren will be activated for 5
seconds and then stop.
Zone 2 LED will be illuminated during the test.
INTERNAL SIREN TEST
Press
The Control Panel internal siren will be activated for
5 seconds and then stop.
Zone 3 LED will be illuminated during the test.
WIRED SIREN TEST
Press
The hardwired siren only will be activated for 5
seconds and then stop.
Zone 4 LED will illuminate during the test.
SIREN SERVICE MODE
The Solar Siren includes a Service Mode facility
which prevents the sirens tamper switch from
triggering an alarm while it is removed from the wall
for maintenance or to change the batteries. After
changing the batteries and refitting in position, the
Solar Siren must be put back into Operating Mode,
otherwise it will not sound in the event of an alarm.
For Siren Service Mode ON (Siren Service Mode)
see page 30 for Siren Service Mode OFF (Siren
Operating Mode) see page 31 for details.
FACTORY SETTINGS
U
ser Access Code: 1 2 3 4
Alarm Duration: 3 minutes
Hardwired Siren: Equal to Alarm Duration
Zone Operating Mode: Intruder (all zones)
Part-Arm: Zones 1-4: Enabled
Z
ones 5-6: Disabled
Instant/Delay: Zone 1: Delay
Zones 2-6: Instant
Entry/Exit Delay: 30 seconds
Entry/Exit Warning Tone: On
Zone Lockout: On
Jamming Detection: Off
Spectra Lighting Status: Off
Spectra Lighting
Time-on period: 3 minutes
RESET FACTORY SETTINGS
1. Press
This puts the system into Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. Remove the DC power jack, then remove and
disconnect one of the back-up batteries.
4. Set jumper link P1 to the ON position.
5. Reconnect the power supply jack.
6. The Control Panel will now reset itself with all
factory settings.
7. The Control Panel will beep and the zone 6 LED
will illuminate for 5 seconds and the factory
settings will be restored to memory.
8. Reconnect and replace the back-up battery.
9. Reset jumper link P1 into the OFF position.
10. Close the Control Panel cover and refit the fixing
screws.
25
2
E
NTER
3
ENTER
4
ENTER
1
4
23
ENTER
, ,
User Access Code
OFF ON
Jumper Link