INSTALLATION
POWER-UP OF THE SOLAR SIREN
1. Connect the 9V PP3 initial power battery to the
battery clip.
Connect the rechargeable battery to the charging
leads. Connect the Red lead to the Red (+ve)
terminal and the Black lead the Black (
-
ve)
terminals. Both indicator LEDs will flash together
in a single long flash to indicate that the unit is
operational.
Important: Once the batteries have been
connected, the Siren will be operational. It is
important that the solar panel receives sufficient
light to maintain the battery charge.
2. Press the anti tamper switch, both indicator LEDs
will flash together four times.
3. Hinge the front cover locating tabs over the top
edge of the back plate and carefully push the base
of the siren cover into place. Secure the Siren
cover in place by refitting the fixing screw in the
bottom edge of the cover. Do not over tighten the
screw as this could damage the thread.
Important: Ensure that the rear tamper switch is
closed when you fit the siren cover to the back-
plate (i.e. listen for the switch to click). If the switch
does not close this will prevent the Solar Siren from
operating correctly. If necessary, remove the siren
cover again and adjust the screw on the back-
plate tamper plunger to ensure the switch closes
when the Siren is secured in position.
4. If fitted remove the protective film covering the
Solar Panel.
TESTING THE SOLAR SIREN
Ensure that the system is in Test mode (see page 20).
1.
Scroll through the top level Test Mode menu until
‘ALARM TEST’ is displayed and press .
2.
Scroll through the menu until ‘Wirefree Siren Test’
is displayed and press .
3. The Solar Siren should operate for a period of
approximately 5s,
4. Press to exit Alarm Test and return to the
top level Test Mode menu.
EXTERNAL CONNECTIONS
The Control Unit incorporates a terminal block for
connection of hard-wired Zones (7-10) and a wired Siren.
The connection terminal block is located inside the
Control Panel behind the front cover.
To access the
terminal block:
Press , ,
This puts the system into Test Mode and prevents an
alarm occurring.
Undo the two fixing screws on the top edge of the
Control Panel and open the front cover.
Before making any connections, ensure that the
memory jumper link P1 is in the ’OFF’ position and
1
2
3 4
ENTER
T1 T2 GND T3 T4 N.C. CN.O.GNDGNDTAMP GND B+ V+ OUT GND
Permanent
12Vdc power
supply output
(100mA max.)
Latching
relay contacts
(Volt-free)
Hardwired Zone
Connections
(Using
Normally-Closed
contacts)
Switched
12Vdc output for
wired Siren
(300mA max.)
T1
T2
GND
T3
T4
N.C.
C
N.O.
GND
GND
TAMP
GND
B+
V+
OUT
GND
Tam per circuit
connections for
wired Siren
Not Used
Terminal
Block
Reset
Jumper
Link P1
Terminal Block Detail
External Tamper Switch
Jumper Link P51
SA5 19
The Siren should not be operated repeatedly
during installation and testing, as this will
rapidly drain the battery. It is recommended
that the Siren be left for at least 24 hours in
order to charge the battery before the system
is Armed.