11
3. Ensure that DIP switch 5 of SW3 on the main
board is set to
ON (“C.U.”) for use with this
alarm system.
4. DIP switch 1 marked “ALARM TIME” is used to
limit the maximum period for which the external
siren will sound before it will be automatically
shut down:
ON 3 minutes
OFF 1 minutes
5. DIP switch 2 marked “AJ” controls the anti-
jamming detection facility in the siren:
ON Jamming Detection enabled
OFF Jamming Detection disabled
6. DIP switch 3 marked “ALARM SOUND” if OFF
will prevent the siren from sounding during an
alarm, (this will not affect the warning beeps):
ON Siren enabled
OFF Siren disabled
7. The Solar Siren will acknowledge signals from
the Remote Control or Keypad by beeping and
flashing the LEDs. It is possible to disable these
acknowledgement beeps DIP switch 4 marked
“BEEP SOUND”.
ON Beeps enabled
OFF Beeps disabled
8. Now see Power-Up of the Solar Siren.
POWER-UP OF THE SOLAR SIREN
Note: The use of ear defenders is advisable when
working in close proximity to the Siren due to the high
sound level produced by this device when triggered.
When the system is first installed, it will automatically
power up in Service Mode. It cannot be switched out
of Service Mode and into Operating Mode until at
least one Remote Control or Keypad is link to it.
9. Connect the rechargeable battery to the battery
leads. Connect the Red lead to the Red (
+
ve)
terminal and the Black lead to the Black (
–
ve)
terminal.
Connect the 9V 6LR61 (PP3) power-up battery
to the battery clip.
10. Press the tamper switch, both indicator LEDs will
flash together several times. The LEDs will then
continue to flash alternately every 5 seconds
thereafter to indicate that the Siren is functioning.
11. If fitted remove the protective film covering the
Solar Panel.
C.U. OR SIREN
C.U. OR SIREN
C.U. OR SIREN
IMPORTANT: Once the batteries have been
connected, the Siren will be operational and it is
important that the solar panel receives sufficient
light to maintain the battery charge. The Siren
should not be operated repeatedly during
installation and testing, as this will rapidly drain
the battery. It is recommended that the Siren be
left for at least a day in order to charge the
battery before the system is Armed.
C.U. OR SIREN