Reset Factory Default Conditions
1. Press
to place the system in Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. S
witch OFF the mains supply to the plug-in PSU
Adapter and remove the plug from the DC power
socket in the Control Panel.
.
4.
Remove either back-up battery and disconnect
the battery leads
.
5. Set jumper link P1 to the ON position.
6.
Reconnect the battery leads and replace the
back-up battery in position.
Reconnect the PSU Adapter plug to the DC power
socket in the Control Panel and switch On the
supply to the PSU Adaptor
.
7.
As the Control Panel powers-up, EEPROM
RESET’ will be displayed while the factory
default conditions are restored to memory.
Once the memory reset has been completed
‘DISARM READY’ will be displayed. The Control
Panel will now be reconfigured with all factory
default settings
.
8. Reset jumper link P1 into the OFF position.
9. Close the Control Panel cover and refit the fixing
screws.
21
Jumper
Link P1
OFF ON